Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 70

Set time switch

Danger of toxic exhaust fumes.
The activated time switch switches on the heater even
when the vehicle is parked. The heater's exhaust can be
toxic in closed spaces (e.g. garages, workshops).
If the vehicle is parked in closed rooms:
– Shut off the (gas) fuel supply to the heater.
– Deactivate the time switch of the Truma CP plus
VarioHeat control panel (OFF).
– Switch off the heater at the Truma CP plus VarioHeat con-
trol panel.
– When air conditioning systems are being operated, the
time switch of the Truma CP plus VarioHeat control
panel must only be used to clearly define the start and
end time for a required period of time.
– If the time switch has been activated (ON), the deacti-
vate time switch menu is displayed first (OFF).
– Select icon in menu bar (4) with rotary push button.
– Change to the setting level by tapping on it.
Enter start time
– Set the hours then the minutes with the rotary push button.
24 h mode
Figure 10
Entering the end time
– Set the hours then the minutes with the rotary push button.
24 h mode
Figure 12
If the start/end point was exceeded during entry, the op-
erating parameters are not taken into consideration until
the next start/end point has been reached. Until then, the op-
erating parameters that have been set outside the time switch
remain valid.
22
12 h mode
= a. m.
= p. m.
Figure 11
12 h mode
= a. m.
= p. m.
Figure 13
Set room temperature
– Depending on the unit that is connected, select the heater
or air conditioning system using the rotary push button
– Tap rotary push button to confirm selection.
– Select required room temperature with rotary push button.
– Tap the rotary push button to confirm the value.
Figure 14
Select fan level
– Select desired fan level with rotary push button.
– Tap the rotary push button to confirm the value.
Figure 15
Activate time switch (ON)
– Activate time switch with rotary push button (ON).
– Tap the rotary push button to confirm the value.
Figure 16
– The time switch remains active until it is deactivated (OFF),
even for several days.
– If the time switch is programmed and active, the time
switch icon flashes.
Deactivate time switch (OFF)
– Change to the setting level by tapping on the rotary push
button.
– Deactivate time switch with rotary push button (OFF).
– Tap the rotary push button to confirm the value.
Figure 17
2

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Varioheat ecoVarioheat comfort

Inhaltsverzeichnis