Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions; Operation While Driving; Regulations; Installation Instructions - Truma VarioHeat Einbauanweisung

Vorschau ausblenden Andere Handbücher für VarioHeat:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Safety instructions

Read the safety instructions and operating
instructions carefully before starting the
appliance.
To ensure safe and proper use, carefully
read and observe the installation and
operating instructions and other documents
supplied with the product, and keep them in a
safe place for future reference. The respective
valid laws, directives and standards must be
observed.
Not following the rules in the operating and
installation instructions can result in serious
material damage and can seriously put at risk
the health or life of persons. The appliance's
operator or user bears sole responsibility for
any damage incurred as a result of this.
Observe the ESD regulations!

Operation while driving

For heating while driving, the UN ECE regula-
tion 122 stipulates a safety shut-off device to
prevent the uncontrolled escape of gas in the
event of an accident. The Truma  MonoControl CS
gas pressure regulation system fulfils this
requirement.
National regulations and rules must be
followed.
If no safety shut-off device (e.g. no
MonoControl CS) is installed, the gas cylin-
der must be closed while driving and notices
must be attached in accordance with the
valid regulations.

Regulations

The rules in the installation and operating
instructions and the respective valid laws,
directives and standards must be observed..
The appliance's operating permit, and conse-
quently also the vehicle's operating permit in
some countries, are rendered void if the regu-
lations are not followed.
Material defect claims, warranty claims and
liability claims against Truma are exclud-
ed in the cases described in the operating
instructions under the heading "Warranty
exclusions".
12

Installation instructions

Only competent and trained persons
(experts) are permitted to install and
repair the Truma product and to carry
out the function test, at the same time
observing the installation and operat-
ing instructions, and the currently rec-
ognised technical regulations. Experts
are persons who, based on their pro-
fessional training, their knowledge and their experience
with Truma products and the relevant standards, can
properly carry out the necessary work and recognise
potential hazards.
Installation instructions

Scope of delivery

Truma VarioHeat
Truma CP classic VarioHeat (analogue CP) or
Truma CP plus VarioHeat (digital CP)
Control panel cable
Installation materials
Operating instructions
Installation instructions
Accessories required
Exhaust system
Optional accessories
Window switch
Warm air parts
Surface-mounted frame
Control panel cable in various lengths (maximum 10 m)

Vehicles

The operating pressure of the gas supply (30 mbar) and of the
heater (see type plate) must be the same.
In Germany, only pressure regulating equipment that complies
with DIN EN 16129 (in vehicles) with a fixed output pressure
of 30 mbar may be used for the gas system. The flow rate
of the pressure regulating equipment must correspond to at
least the maximum consumption of all appliances installed by
the system manufacturer.
If exhaust gas is discharged beneath the floor, it must be en-
sured that the vehicle floor is sealed. In addition, at least three
sides beneath the vehicle floor must be free to ensure that the
exhaust gas can escape unhindered (snow, stone guard etc.).
Cowls must be positioned so that no exhaust gas can enter
into the interior. The exhaust gas system must always be rout-
ed at least as far as the side wall.
Figure 8

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis