16. Error messages

ERROR 2
ERROR 3
ERROR 4
ERROR 5
ERROR 6
ERROR 9
ERROR 11
ERROR MESSAGES
This chapter explains the causes of the errors indicated by the welding machine
and their possible solution. To work with the machine after an ERROR message
press "RESET".
CAUTION: Before starting the equipment check that the power supply has a
frequency between 45 and 55 Hz. An unsuitable frequency could damage the
equipment.
Unacceptable temperature for using the equipment.
Check that the ambient temperature is between -10°C and + 45°C.
Faulty circuit or probe.
Ohm value reading is above the limits stipulated by the manufacturer (ONLY WITH SCANNER).
The ohm value which is in the barcode does not correspond to what is being read by the
machine in the connected accessory.
Faulty reading circuit.
Check the status of the terminal connectors for connection to the bushing and use of the
correct type in relation with the accessory used.
Do not leave the electrofusion joint exposed to sunlight for a long time in the summer; this
could temporarily modify the ohm value of the joint.
Overload in the secondary circuit connected to the accessory.
Connection cables in short-circuit. The accessory has a lower resistance to that declared during
the welding cycle. Check and, if necessary, replace the accessory by using the aligning tools.
Faulty circuit.
Secondary circuit open.
Connected accessory resistance interrupted.
Cables disconnected or faulty connectors. Check and, if necessary, replace the accessory
by using the aligning tools.
Faulty circuit.
The programmed power supply voltage cannot be maintained.
Frequency voltage modifications in the power supply line.
Check the regularity of the power supply line and/or of the power generator set. Also
check that the power supply voltage is between 190 and 260V.
Faulty circuit.
Short-circuit in the secondary circuit connected to the accessory.
Short-circuit in the secondary circuit connected to the accessory.
Short-circuit in the secondary circuit connected to the accessory
Short-circuited connection cable. Accessory resistance short-circuited during the welding cycle.
Perform a control and, if necessary, replace the accessory using the alignment devices.
Faulty circuit.
Memory full.
The 300 cycles which can be registered have been completed. Delete the data by using a
serial type printer or with the programme "Hyper Terminal". Otherwise, if this operation
cannot be carried out it is possible to proceed working by pressing "VALID". In this case,
the data of the first welding operation performed are deleted.