The electrofusion welding equipment is designed for use in conjunction with a scanner. When used
in manual mode, the required voltage and time values for welding are indicated in the accessory or
bushing.
The voltage value is normally indicated using "V", whilst the time may be indicated using "T" or
"Sec".
It is assumed that the time value refers to seconds and not to minutes.
The way the time/voltage data are obtained is explained below should these not be explicitly
indicated in the accessory/bushing:
Example 1 (specific indication under the barcode)
(voltage indication)
Example 2
Example 3 barcode with 24 characters (24 numbers)
Note: The numbers shown above are merely an example.
If there were no indication, by reading the barcode it is possible to find the necessary information
by following these instructions: start by reading the barcode from the left, go to position 13-14,
where the voltage value (V) is indicated; the welding time will be indicated in positions
in seconds.
If, even with a barcode, it were not possible to f ind time/voltage values the manufacturer of the
electrofusion accessory would have to be contacted to obtain the values required to perform the welding
cycle.