Quantity of re-greasing (approx. value)
Grease Quantity
Pressure Side
Pump Size
MPV 100.1
MPV 100.2
MPV 125.1
MPV 125.2
Relubrication Intervals in Operating
Pump Size
3550
-1
[min
] [min
MPV 100.1
3300
MPV 100.2
3300
MPV 125.1
2500
MPV 125.2
2500
Relubrication intervals with activation durations of
approx. 50% (cycle duration 1 hour).
For activation durations of approx. 100%, halve the
relubrication intervals.
If the pump is left non-operational for a longer
time, the grease in the bearings should be
changed after 2 years.

7.5 Coupling

MPB Design:
No adjustment work is required.
MPV Design:
Check the clearance in the coupling components
regularly approx. every 1000 operating hours, but at
least 1x year, the radial clearance in the coupling parts
must be checked.
For couplings with rubber pads the following applies:

8. Dismantling and repair of pump

8.1 General remarks

Repair to the pump or pump system may only
be carried out by authorised skilled personnel or
by the manufacturer's specialist staff.
When disassembling the pump pay attention to
chapter 2 and chapter 4.1.
For mounting and repair you can order specialized
personnel if you want.
If dangerous liquids are pumped the appropriate
disposal of the handled liquid is necessary
before the disassembly of the pump. Pay
attention to the fact, that even in drained pumps
there are remainders of the handled liquid. If
necessary the pump must be flushed or
decontaminated. Laws must be observed,
otherwise danger to health is existing!
Before the disassembly the pump has to be
secured in such a way, that it can't be started.
The pump casing must be drained and without
pressure.
MPB 100-english
Article No 771074115
3
[cm
]
23,0
23,0
33,0
33,0
Hours
2950
2200
1750
1450
-1
-1
-1
] [min
] [min
] [min
3800
4500
5000
5500
3800
4500
5000
5500
3300
4300
4800
5000
3300
4300
4800
5000
page 87
Unless a clearance in the couplings is necessary, the
coupling pads may wear out to approximately ¼ of
their usual thickness, before they have to be changed.
To measure the clearance in the coupling place a
mark on the O.D. of each coupling hub (see following
pic). Then fixing one hub, turn the opposite hub as far
as possible. Then measure the distance (∆S
between the marks of the coupling. If this measure
exceeds the value given in the chart, the packing must
be replaced. They must be replaced in sets.
-1
]
Size
80
95 110 125 140 160 180 200 225 250 280 315 350 400
[mm] 5,0 6,0 7,0 8,0 8,5 8,0 8,0 8,5 9,0 10,0 11,5 10,5 11,5 13,0
∆S
v
If wear is heavy, it must be assumed that the
motor is not properly aligned with the pump or
that the distance between the coupling sections
has changed. Replace worn elements and re-
install or adjust coupling, as described in
chapter 5.3.

7.6 Cleaning of pump

The
pump
pressurised water - water will get into the
bearings.
Dirt on the outside of the pump has an adverse effect
on transmission of heat. The pump should therefore
be cleaned with water at regular intervals (depending
on the degree of dirt).
All locking devices in the suction- and discharge-
pipe must be closed.
All parts must have taken on the temperature of
the environment.
Secure disassembled pumps, units or single
parts against tipping over or rolling off.
While disassembling the pump use of an open
flame (blowlamp, etc.) only, when there is no
danger of setting fire, cause an explosion or
cause injurious vapours.
Never apply heat to remove the impeller nut.
Use of heat may result in severe physical injury
and property damage.
Use original spare parts only. Pay attention to
the right materials and the matching design.