Button for light functions e
Sensor
1 × short
10 sec. - 30 min.
max. 4 hours.
Sensor mode
Permanent light mode
The Sensor Switch basically
Button 1 × 'ON'
operates in sensor mode.
The connected light is set
The light is switched 'ON' for
to permanent light for 4
the preset time in response
hours (red LED illuminates).
to movement within the
After this period, the Sensor
detection zone.
Switch immediately returns
to sensor mode (red LED
'OFF').
Permanent light can be
interrupted before this time
elapses by pressing the
button (red LED 'OFF').
1 × 3 sec.
OFF
Permanent light OFF mode
Press button for 3 sec.
The connected light is
switched 'OFF' (red LED
flashes). By briefly pressing
the button again, the Sensor
Switch returns immediately
to sensor mode (red LED
'OFF').
- 18 -

Troubleshooting

Malfunction
Cause
Sensor Switch
Fuse blown,
W
without power
not switched 'ON'
Short circuit
W
Sensor Switch
Light bulb burnt out
W
does not switch 'ON'
Twilight setting in night-
W
time mode during day-
light mode
Additional two-way
W
switch 'OFF'
Fuse blown
W
Permanent light 'OFF'
W
mode switched 'ON'
Sensor Switch
Continued movement
W
does not switch 'OFF'
within the detection zone
Switched 'ON' light is
W
within detection zone of
IR 180 AP and switches
'ON' again as a result of
temperature change
Permanent light operation
W
switched 'ON'
(red LED illuminates)
Other Sensor Switch is
W
connected in parallel and
still active
Sensor Switch
Switched 'ON' light is
W
keeps switching 'ON'/'OFF'
within IR 180 AP detec-
tion zone
Animals moving in
W
IR 180 AP detection zone
Curtains, flowers, etc.
W
move within the detection
zone of the HF 360 AP
and cause switching
again by motion
Operation/Maintenance
The Sensor Switch is
burglary alarm systems,
suitable for automatic
since it lacks the sabotage
switching of light. The unit
protection prescribed for
is not suitable for special
this purpose.
Remedy
Replace fuse;
W
switch 'ON' mains switch,
check wiring with voltage
tester
Check connections
W
Replace light bulb
W
Readjust
W
Switch power 'ON'
W
New fuse,
W
check connection
if required
Switch power 'ON'
W
Check detection zone
W
Check detection zone
W
Switch 'OFF' permanent
W
light operation
Await time setting of the
W
other Sensor Switch
Check detection zone
W
Check detection zone
W
Check detection zone
W
The surface should be
cleaned if dirty with a damp
cloth (without cleaners).