the warranty period expires. STEINEL shall assume
no liability for the costs or risks involved in returning
a product.
For information on making claims under the
terms of the warranty, please go to
www.steinel-professional.de/garantie
12. Technical specifications
Dimensions (H × W × D)
144 × 113 × 172 mm
Output
Incandescent lamps, max. 2500 W at 230 V *
Fluorescent lamps, max. 1000 VA at 230 V (cos
Starting current:
C < 176 μF, max. 8 LED/fluorescent lamps
Electronic ballast *
Voltage supply
220-240 V AC, 50 / 60 Hz
Angle of coverage
300° with 180° angle of aperture as well as sneak-by guard
and coverage directly below the sensor. Capability of masking out
detection zone in segments
Reach
Adjustable in 3 directions via control dial independently of each other,
(2-20 m, temperature-stabilised)
Sensor system
4 sensors, 6 detection levels for long-distance detection
and 5 for sneak-by guard,
1360 switching zones
Time setting
5 s - 15 min, pulse mode (approx. 2 s)
Twilight setting
2-2000 lux
Manual override (permanent light)
selectable (4 h)
Permanently OFF
selectable (4 h) / (via remote control only)
IP rating
IP54 through 2K technology
Temperature range
-20°C to +50°C
For eNet version only
Radio frequency
868.3 MHz
Transmitter power
max. 20 mW
Reach in the open
max. 100 m
*
1)
VDE tested
2)
*
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
If you have a warranty claim or
would like to ask any questions
regarding your product, you are
welcome to call us at any time
on our Service Hotline
01733 366700.
1)
= 0.5)
2)
– 18 –

13. Troubleshooting

Malfunction
Cause
No power at the sensor
Fuse faulty, not switched ON,
break in wiring
Short circuit
Sensor will not switch ON
Twilight control set to night
mode during daytime operation
Bulb faulty
Mains power switch OFF
Fuse faulty
Detection zone not properly
targeted
Sensor will not switch OFF
Continuous movement in the
detection zone
Light being operated is located
in the detection zone and keeps
switching ON as a result of
temperature change
Light being operated is in man-
ual override mode (LED ON)
Sensor keeps switching
Light being operated is
ON/OFF
located in the detection zone
Animals moving in the
detection zone
Sensor responds
Wind is moving trees and
when it should not
bushes in the detection zone
Cars on the road are being
detected
Sunlight is shining on the lens
Sudden change in temperature
caused by weather (wind, rain,
snow) or air discharged from
fans, open windows
Change in sensor's reach
Differing ambient temperatures
Remedy
Replace fuse, turn ON power
switch, check lead with voltage
tester
Check connections
Adjust setting
Change bulb
Switch ON
Fit new fuse, check connection
if necessary
Readjust
Check zone and readjust or
fit shrouds if necessary
Change detection zone or
fit shrouds
Deactivate manual override
Change zone or fit shrouds,
increase distance
Change detection zone or
fit shrouds
Change detection zone
Change detection zone
Mount sensor in a sheltered
place or change detection zone
Change detection zone,
mount in a different place
Adjust reach via reach controller
(Fig. 6.2), apply shrouds where
necessary (Fig. 6.4)
– 19 –