Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - STEINEL Studioline IS 2180-5 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Studioline IS 2180-5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Wiring examples
1. Light without neutral conductor
3. Connection using series switch for
manual and automatic operation
1) e.g. 1-4 x 100 W filament bulbs
2) Service load, light of 1000 W max. (see Technical specifications)
3) IS 2180-5 connection terminals
4) Indoor switch
5) Indoor series switch, manual, automatic
6) Indoor double-throw switch, automatic, permanent light ON
Operation/Maintenance
The Infrared Sensor is
Weather conditions may
suitable for switching light
affect the way the motion
ON and OFF automatically.
detector works. Strong
The unit is not suitable for
gusts of wind, snow, rain or
special burglary alarm
hail may cause the light to
systems since it lacks the
come ON when it is not
tampering protection
wanted because the sensor
prescribed for this purpose.
is unable to distinguish
20
2. Light with neutral conductor
4. Connection to double-throw switch
for permanent light ON and automatic
operation
Setting I: automatic operation
Setting II: manual operation for permanent
light ON
Important: the unit cannot be switched OFF,
but operated only at settings I and II.
sudden changes of tem-
perature from sources of
heat. The detector lens
may be cleaned with a
damp cloth it it gets dirty
(do not use cleaning
agents).

Troubleshooting

Malfunction
Cause
IS 2180-5
Fuse faulty; not switched
a
without power
ON
Short circuit
a
Mains switch OFF
a
IS 2180-5
Twilight control set to
a
will not switch ON
nighttime mode during
daytime operation
Bulb faulty
a
Mains power switch OFF
a
Fuse faulty
a
Detection zone not
a
properly targeted
IS 2180-5
Continuous movement in
a
will not switch OFF
the detection zone
Light is in detection zone
a
and keeps switching on
as a result of tempera-
ture change
Set to continuous
a
operation by indoor
series switch
IS 2180-5 keeps
Light is in detection
a
switching ON/OFF
zone
Animals moving in
a
detection zone
Heat source (e.g.
a
extractor hood outlet) in
detection zone
IS 2180-5 switches ON
Wind is moving trees
a
when it should not
and bushes in the
detection zone
Cars in the street are
a
being detected
Sudden temperature
a
changes due to weather
(wind, rain, snow) or air
expelled from fans or
open windows
Remedy
Renew fuse, switch on
a
mains power switch,
check wiring with voltage
tester
Check connections
a
Switch on
a
Adjust setting
a
Change light bulb
a
Switch on
a
Renew fuse, check
a
connection if necessary
Re-adjust
a
Check detection zone
a
and re-adjust if
necessary or fit shrouds
Re-adjust zone or apply
a
shroud
Set series switch to
a
automatic mode
Adjust detection zone or
a
fit shrouds, increase
distance
Adjust detection zone or
a
fit shrouds
Adjust detection zone or
a
fit shrouds
Blank off sections using
a
shrouds
Blank off sections using
a
shrouds
Adjust detection zone or
a
change site of
installation
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis