Herunterladen Inhalt Inhalt Diese Seite drucken

PeakTech 1360 Bedienungsanleitung Seite 123

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Auto: Automatic mode and acquire waveform without triggering.
Trig: Trigger detected and acquire waveform.
Ready: Pre-triggered data captured and ready for a trigger.
Scan: Capture and display the waveform continuously.
Stop: Data acquisition stopped.
4.
Click to show/hide the touchable menu pane (only for touchscreen). (see
"Operate the Menu through Touchscreen" on P17)
5. The two blue dotted lines indicates the vertical position of cursor measurement.
6.
The T pointer indicates the horizontal position for the trigger.
7.
The pointer indicates the trigger position in the record length.
8.
It shows present triggering value and displays the site of present window in
internal memory.
9.
Touchable icon is to enable (
(only for touchscreen).
10. It shows setting time (see "Config" on P60).
11. WIFI is activated (see "Communication with Android Device via Wi-Fi
(Optional)" on P97).
12. It indicates that there is a USB disk connecting with the oscilloscope.
13. Indicating battery power status (see "Display" on P60).
14. Multimeter window.
15. The pointer shows the trigger level position.
16. The waveform of CH1.
17. The two blue dotted lines indicate the horizontal position of cursor measurement.
18. The waveform of CH2.
19. It indicates the measured type and value of the corresponding channel. "T" means
period, "F" means frequency, "V" means the average value, "Vp" the peak-peak
value, "Vr" the root-mean-square value, "Ma" the maximum amplitude value,
"Mi" the minimum amplitude value, "Vt" the Voltage value of the waveform's
flat top value, "Vb" the Voltage value of the waveform's flat base, "Va" the
amplitude value, "Os" the overshoot value, "Ps" the Preshoot value, "RT" the rise
time value, "FT" the fall time value, "PW" the +width value, "NW" the -Width
value, "+D" the +Duty value, "-D" the -Duty value, "PD" the Delay A->B
value, "ND" the Delay A->B
RMS, "WP" the Screen Duty, "RP" the Phase, "+PC" the +Pulse count, "-PC"
the - Pulse count, "+E" the Rise edge count, "-E" the Fall edge count, "AR" the
Area, "CA" the Cycle area.
20. Current trigger type:
Rising edge triggering
Falling edge triggering
Video line synchronous triggering
Video field synchronous triggering
3.Junior User Guidebook
) or disable (
value, "TR" the Cycle RMS, "CR" the Cursor
9
) the touchscreen controls

Werbung