12.3 Additional Functions

Special functions can put the product in a new „Special mode" in which not all of the functions
and behaviours described above apply. In this case, all changes are listed explicitly.

12.3.1 Time Limitation Alarm (HOLDALARM)

The product has the option of interrupting alarm mode at certain times. This corresponds to
automatic change to mode „ALARM ENABLE" or „ALARM DISABLE". Use the following
command:
SET HOLDALARM
<Start_hh> <Start_mm> <Stop_hh> <Stop_mm> <Day(s)> #1513
The parameter „Day(s)" represents the week day/s:
mo
= Monday
tu
= Tuesday
we
= Wednesday
th
= Thursday
fr
= Friday
sa
= Saturday
so
= Sunday
all
= daily
The parameters „Start_hh" and „Start_mm" represent the starting time as of which the alarm
mode is to be interrupted. Single-digit values are prefixed with a „0" (i.e. enter „09" instead of
„9").
The parameters „Stop_hh" and „Stop_mm" represent the end time until when alarm mode is
to be interrupted. Single-digit values are prefixed with a „0" again (i.e. enter „09" instead of „9").
When using different times for each day, several commands are necessary.