Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Voltage Monitoring (Voltage) - Conrad GKA100 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für GKA100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

12.2.3 Operating Voltage Monitoring (VOLTAGE)

The device may verify the power supply voltage (car battery) and inform (i.e. send an alarm
text message) when the voltage is too low or fails entirely (e.g. by manipulation at the vehicle).
The device is equipped with an internal Li-Ion battery to ensure the device's function for a
certain time and thus to enable continuation, e.g. of the GPS function.
Command to set the min. voltage:
SET VOLTAGE <Voltage> #1513
The parameter „Voltage" can be set from 600 (= 6 V) to 3200 (= 32 V).
If the voltage is set to 600 (lower threshold), the alarm is switched off.
The alarm text message will include a summary of the current voltage as well as the current
battery charge condition.
GKA100 1.xx
....................
ALARM
Power low
Accu 100%
Voltage 11.0 V
To verify the desired settings, use the command:
TEST VOLTAGE #1513
Send the following command to reset the factory settings (basic position is „off"):
RESET VOLTAGE #1513