12.5 System Functions

This chapter describes technically sophisticated functions. The default settings are already set
for most application areas. Therefore, we recommend only adjusting these parameters in the
respective application cases.
If the product has any malfunctions, activate the default settings again first.
If you need to contact our hotline, ensure that the device is back in its standard configuration.

12.5.1 Time between Two Alarm Messages (IDLEALARM)

In case of alarm, the product will send an alarm message. Further messages of the same type
are only sent if the corresponding alarm situation was left for a specified period (factory
settings: 5 minutes). This period can be changed.
Use the following text message command for this:
SET IDLEALARM <Time> #1513
The parameter „Time" can be set between 1 and 240 minutes.
Example:
SET IDLEALARM 15 #1513
The period between alarm messages is now 15 minutes.
Attention!
In this period, you will not receive any new messages on alarm situation changes.
Within this period, however, every user is able to check his parameters.
Reset to factory settings:
The following command resets the settings to factory settings (5 minutes):
RESET IDLEALARM #1513
Checking settings
The settings made may be reviewed with the following command:
TEST IDLEALARM #1513