Example:
The switching input was configured to trigger an alarm at HIGH level. The IDLE countdown
starts when the input IN1 has reached the LOW condition.
If the alarm condition of input IN1 is reached again during the IDLE time (HIGH level), the
countdown is reset but no alarm is triggered (IDLE time did not elapse). Only when the input
IN1 has retained the LOW condition without interruption for at least the set IDLE time will IN1
be able to trigger an alarm text message again.
Reason: This function protects you from unnecessarily high text message costs.