Herunterladen Inhalt Inhalt Diese Seite drucken

In- And Outputs; Relay Outputs (Out1, Out2) - Conrad GKA100 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für GKA100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

12.2 In- and Outputs

This is an autonomously working alarm reporting device. Incorrect settings or
connections may cause undesired text messages to be sent!
Never enter the phone number that belongs to the SIM card that is inserted in the
module! Also never enter any phone numbers from any other car alarm systems or
reporting devices.

12.2.1 Relay Outputs (OUT1, OUT2)

The two outputs OUT1 and OUT2 can be switched on or off via a text message command to
the car alarm system. Every output is put on a relay with alternate contact.
The following commands can be used to switch the outputs on or off.
To switch on output 1 (OUT1), use the command:
SET OUT1 #1513
To switch off output 1 (OUT1), use the command:
RESET OUT1 #1513
To switch on output 2 (OUT2), use the command:
SET OUT2 #1513
To switch off output 2 (OUT2), use the command:
RESET OUT2 #1513
Never use any higher voltage than 30 V/DC and no current load above 2 A.
Larger consumers require corresponding external relays.
The relays, cables and PCB must be secured externally against overload. If
required, an external fuse must be used.
Special functions wireless remote control (RF) / ALARM:
The relays may be additionally instructed to react to certain events. The following SET
commands are available for this.
SET OUT1/OUT2 RF <time> [ENABLE/DISABLE] #1513
SET OUT1/OUT2 ALARM <time> #1513
97

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

841086