In the following, the PIN assignments are described.
1. LED + external alarm LED
2. LED – external alarm LED
3. P+ switching plus
4. Not assigned
5. IN1 switching input a
6. IN1 switching input b
7. IN2 switching input a
8. IN2 switching input b
All relays are in the condition „OFF/RESET".
The PIN assignment of the product is printed on the reverse of the device.
However, observe that the PIN assignment printed on for the connection "OUT2" is,
unfortunately, incorrect in the first series. The above assignment is correct.
9. OUT2 relay output common
10. OUT2 relay output closer
11. OUT2 relay output opener
12. OUT1 relay output opener
13. OUT1 relay output common
14. OUT1 relay output closer
15. VCC voltage supply plus/+
16. GND voltage supply minus/-