• Wear safety shoes, gloves, safety goggles and a
breathing mask.
• Keep hands and feet away from the moving parts.
• Do not reach into the mixing drum while it is running.
• Do not put any objects into the mixing drum while it
is running, e.g. shovel or similar.
• Danger of injury when the mixing drum is rotating.
• The concrete mixer may only be operated with orig-
inal spare parts.
• Repairs to the concrete mixer may only be carried
out by authorised specialist companies.
• Do not leave ready-to-use concrete mixer unattended.
• Switch off the machine and pull out the mains plug
when leaving the workstation.
6. Residual risks
The product has been built according to state-of-
the-art and the recognised technical safety rules.
However, individual residual risks can arise during
operation.
• Danger of injury due to rotating parts.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Before performing setting or maintenance work,
switch the motor off and unplug the mains plug.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with the
operating manual as a whole are observed.
• Avoid accidental start-ups of the machine: Make
sure that the ON/OFF switch is set to "0" before in-
serting the plug into the socket.
• Use the tool that is recommended in this operating
manual. This is how to ensure that your machine
provides optimum performance.
• Keep your hands away from the working area when
the product is in operation.
m Warning! This power tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain cir-
cumstances.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
26 | GB
7.
Technical data
Engine
Engine output
Max. drum speed
Full load current
Capacity
Diameter of drum
opening
Protection category
Operating mode*
Protection class
Dimensions
Weight
Subject to technical changes!
*S6 30 %: Continuous duty with intermittent loading
(operating time 10 min.)
In order avoid impermissible overheating of the motor,
the motor should be driven for only 30% of the operat-
ing time with the stipulated nominal power and must
then continue to run with no load for the remaining 70%
of the operating time.
Noise and vibration
m Warning:
Noise can have serious effects on your health. If the
machine noise exceeds 85 dB, please wear suitable
hearing protection.
Noise data
The noise levels have been determined in accordance
with 2005/88/EC.
Sound pressure level L
Uncertainty K
Sound power level L
Uncertainty K
Guaranteed sound power
level L
WA
www.scheppach.com
MIX160
230 V / 50 Hz
0.65 kW
29.5 rpm
2.94 A
160 l
390 mm
IP45D
S6 30%
II
1260 x 850 x
1350 mm
53.8 kg
MIX160
69.75 dB
pA
2.77 dB
pA
90.74 dB
WA
1.20 dB
WA
92 dB
MIX180
230 V / 50 Hz
0.8 kW
29.5 rpm
3.62 A
180 l
390 mm
IP45D
S6 30%
II
1260 x 850 x
1400 mm
56.5 kg
MIX180
67.98 dB
5.14 dB
91.78 dB
1.40 dB
93 dB