Installing the RECERBO:
Replacing the Fil-
Removing the GalvoFIL:
ter PC Board (Gal-
voFIL)
104
(4)
(3)
(4)
(3)
(1)
(2)
(2)
NOTE! In the next two steps, en-
sure that no components are dam-
aged.
Remove the holder (3) from the
5
RECERBO
Remove the breakaway PC board (4)
6
from the faulty RECERBO
The breakaway PC board of the new
1
RECERBO must also be removed and
returned with the faulty RECERBO to
Fronius.
NOTE! If the breakaway PC board
is forgotten or not inserted correct-
ly, the inverter will show a status
code (482) on the display.
Insert the previously separated brea-
2
kaway PC board (4) on the internal
side of the new RECERBO.
Mount the RECERBO holder (3) on the
3
new RECERBO
- thread the wire up
- press down.
NOTE! All guide pins and bolts
must be engaged.
Insert the new RECERBO assembly
4
The locks (2) on the RECERBO holder
5
must be fully engaged in the housing
frame
Insert the external fan cable in the cab-
6
ling (1)
Insert the Datamanager card, close the
7
inverter and insert into the wall bracket
(see "Replacing the Datamanager
Card" and "Opening and Closing De-
vice" sections)

Quicklinks ausblenden: