Hang the power module lid up on the
2
(5)
fastening pins (5)
While the device is still at an angle, pull
3
the power module lid down and tilt the
basic frame
CAUTION! This is the only way to
ensure that the seal foam is cor-
rectly positioned and working
properly
Mount power module lid with 4 screws
4
5x18 TX25 including gaskets (4)
(4)
[2.5 Nm | 1.84 ft lb]
NOTE! If the screws no longer
grip properly, replace them with
screws 5x25 TX25 [42,0401,4231]
(4)
NOTE! To avoid damage to the
basic frame, the inverter must not
exceed an angle of 11°.
Hang the inverter on the top side and
5
(3)
snap it into place in the wall bracket
Mount 2 screws 5x25 TX25 (3) and fix
6
to the wall bracket securely
[2.5 Nm | 1.84 ft lb]
Mount all plug connections if there are
7
any
Mount DATCOM lid with 2 screws 5x25
7
TX25 (2)
[2.5 Nm | 1.84 ft lb]
Set DC disconnector (1) to ON
8
(2)
97