Replacing the
Removing the Datamanager card:
Datamanager
Card
WLAN Option
102
(2)
(1)
(3)
WARNING! Observe the safety
rules (see the beginning of the
"Safety" section)
Take the inverter out of the wall bra-
1
cket and open it (see "Opening and
closing the device")
Datamanager:
Unplug the 12-pin plug connection (1)
2
from the Datamanager PC board
Use a flat spanner to take off the anten-
3
na (2)
Undo the 4x8 TX20 Taptite screw (3)
4
Unplug the Datamanager card from the
5
Recerbo PC board and remove it
Datamanager 2:
Unplug the 16-pin plug connection (1)
2
from the Datamanager PC board
Use a flat spanner to take off the anten-
3
na (2)
Undo the 4x9 TX20 Taptite screw (3)
4
Unplug the Datamanager card from the
5
Recerbo PC board and remove it