Inserting the Datamanager card:
Replacing the RE-
Removing the RECERBO:
CERBO display
PC board
(2)
(1)
(3)
(1)
(2)
(2)
Insert the new Datamanager card and
1
connect it to the Recerbo PC board
Datamanager:
Fit the Datamanager PC board with a
2
4x8 TX20 Taptite screw (3)
[1.2 Nm]
Use a flat spanner to fit the antenna (2)
3
[0.6 Nm]
Fit the 12-pin plug connection (1) to the
4
Datamanager PC board
Close the inverter and place it in the
5
wall bracket (see "Opening and closing
the device")
Datamanager 2:
Fit the Datamanager PC board with a
2
4x9 TX20 Taptite screw (3)
[1.2 Nm]
Use a flat spanner to fit the antenna (2)
3
[0.6 Nm]
Fit the 16-pin plug connection (1) to the
4
Datamanager PC board
Close the inverter and place it in the
5
wall bracket (see "Opening and closing
the device")
WARNING! An electric shock can
be fatal. Follow the safety rules
(see start of "Safety" chapter).
Remove the inverter from the wall bra-
1
cket, open, and remove the Datamana-
ger card (see "Opening and Closing
the Device" and "Replacing the Data-
manager Card" sections)
Remove the external fan cable from
2
the cabling (1).
Push the locks (2) on the RECERBO
3
holder upward
Remove the RECERBO assembly
4
103