Replacing the fil-
Removing SymoFIL:
ter PC board –
SymoFIL
Installing SymoFIL:
(1)
(2)
(3)
(4)
(4)
(2)
WARNING!
Follow the safety rules (see the begin-
ning of the "Safety" section)
Remove the inverter from the wall bra-
1
cket, open, and remove the Recerbo
without dismantling the snap-off PC
board (see "Opening and Closing the
Device" and "Replacing the Display
PC Board (Recerbo)" sections)
Disconnect and pull out all cable and
2
plug connections (1-2) from the Symo-
FIL
Unlock the PC board holder in the
3
(3)
Datcom area (3)
Pull the PC board holder (3) in the
4
direction of the SymoFIL and remove
Undo the nine 4x9 TX20 screws (4)
5
Undo the ground connection (5) and
6
detach
Pull out and remove the SymoFIL
7
(4)
(5)