Code
Description
567
GVDPR active
601
Internal communication er-
ror
602
Auto-test Italy failed
605
Internal communication er-
ror of ISO test controller
606
Internal voltage supply of a
microcontroller faulty
Service Class 7
Class 7 status codes concern the inverter control unit, configuration and data recording,
and can directly or indirectly affect grid feed operation.
Code
Description
701*
LN node type outside of
range
702*
Recerbo buffer full
703*
LN transmission buffer full
705*
LN number double assign-
ment
706* - 707*
Communication error for
key activation
711*
EEPROM error
712*
Error when writing to EE-
PROM
713
EEPROM data could not be
read completely
714* - 715*
Error when reading EE-
PROM
721
Error when writing to EE-
PROM
722* - 726*
Error when reading/writing
to EEPROM
727* - 730*
EEPROM backup faulty
84
Behavior
1. Grid voltage too high
2. Grid faults
3. Incorrect setting
1. Occurs once
2. Occurs constantly
1. Auto-test Italy was started
and not completed
1. Occurs once
2. Power filter
1. Occurs once
2. Power filter
Behavior
1. Incorrect LN number
2. EEPROM faulty
1. Problems with LN ring
2. Recerbo faulty
1. Problems with LN ring
2. Recerbo faulty
1. LN number exists 2 times
1. Occurs once
2. Recerbo faulty
1. Recerbo faulty
1. Occurs once
1. Occurs once
2. Recerbo faulty
1. Occurs once
2. Recerbo faulty
1. Occurs once
2. Recerbo faulty
1. Occurs once
2. Recerbo faulty
1. Occurs once
2. Recerbo faulty
3. SSP faulty
Remedy
1. Automatically corrected
2. Software update
3. Check settings
1. Restart inverter
2. Replace inverter
1. Reload setup
1. Restart inverter
2. Replace filter PC board
1. Restart inverter
2. Replace filter PC board
Remedy
1. Enter LN number again
2. Replace Recerbo
1. Check LN ring
2. Replace Recerbo
1. Check LN ring
2. Replace Recerbo
1. Change LN number; LN
number must be unique
1. Automatically corrected
2. Replace Recerbo
1. Replace Recerbo
1. Automatically corrected
1. Automatically corrected
2. Replace Recerbo
1. Automatically corrected
2. Replace Recerbo
1. Automatically corrected
2. Replace Recerbo
1. Automatically corrected
2. Replace Recerbo
1. Automatically corrected
2. Replace Recerbo
3. Replace inverter