Herunterladen Inhalt Inhalt Diese Seite drucken

Clipping The Inverter Onto The Mounting Bracket - Fronius Eco Installationsanleitung

Vorschau ausblenden Andere Handbücher für Eco:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Clipping the In-
verter onto the
mounting bracket
Due to the high weight, the inverter should be clipped to the mounting bracket in sets of
two.
The fixing screws in the data communication area of the inverter are used to fix the inverter
to the mounting bracket. Fixing screws must be properly tightened to ensure correct con-
tact between the inverter and the mounting bracket.
Visually inspect the seal of the Datcom lid for damage. A damaged or defective Datcom lid
may not be installed on the device.
44
WARNING! An inadequate ground conductor connection can cause serious inju-
ry and damage to property. The housing screws provide an adequate ground con-
ductor connection for grounding the housing and should not be replaced under
any circumstances by other screws that do not provide a reliable ground conduc-
tor connection.
NOTE! The inverter is fitted with a lock for safety reasons, which allows the invert-
er to be pivoted in the mounting bracket only when the DC main switch is off.
-
Only clip on and pivot the inverter in the mounting bracket when the DC main
switch is off.
-
Do not use excessive force to clip on the inverter and pivot it.
CAUTION! Risk of damage to the inverter due to improperly tightened fixing
screws.
Improperly tightened fixing screws may cause arcs to occur when the inverter is
operated, which may lead to fire. Always tighten the fixing screws with the speci-
fied torque.
The warranty claims will not apply if the
screws are tightened with an incorrect tor-
que.