Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Dc Disconnector - Fronius Galvo 208-240 1.5-1 Serviceanleitung

Netzgekoppelter wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Replacing the DC
Removing the DC disconnector:
Disconnector
Installing the DC disconnector:
98
(1)
(2)
(3)
(3)
(3)
(3)
(3)
(3)
WARNING! Follow the safety
rules (see start of "Safety" chap-
ter)
Remove the inverter from the wall bra-
1
cket (see "Opening and Closing De-
vice" section)
WARNING! Take safety precau-
tions. Due to DC voltage, follow
safety rules!
Disconnect AC and DC lines from the
2
terminal block of the DC disconnector
Remove the holder (1) and the shift
3
knob with shaft (2)
Loosen 4 screws 4x9 TX20 (3) and re-
4
move DC disconnector
Insert the new DC disconnector and
1
mount with 4 screws 4x9 TX20 (3)
[2 Nm | 1.48 ft lb]
NOTE! If the two left GND con-
tacts of the terminal block are not
required, tighten these at 1.6 Nm |
1.18 ft lb.

Quicklinks ausblenden: