Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The External Fan - Fronius Galvo 208-240 1.5-1 Serviceanleitung

Netzgekoppelter wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Replacing the Ex-
Removing the external fan:
ternal Fan
(3)
(1)
(2)
(2)
(1)
(3)
(6)
(4)
Insert the shift knob with shaft (2) and
2
fix with folder (1)
WARNING! Take safety precau-
tions. Due to DC voltage, follow
safety rules!
Connect AC and DC lines from the ter-
3
minal block of the DC disconnector
Insert the inverter into the wall bracket
4
(see "Opening and Closing Device"
section)
WARNING! Follow the safety
rules (see start of "Safety" chap-
ter)
Remove the inverter from the wall bra-
1
cket and open (see "Opening and Clo-
sing Device" section)
Loosen fan cable (1) for GalvoFIL and
2
remove from the cabling (2)
NOTE! Carefully turn the inverter
so that the rear of the inverter can
be accessed.
Loosen 2 screws 5x14 TX25 (3)
3
Loosen the locks (6) for the air duct on
4
both sides
Remove the seal plugs (4)
5
Carefully remove the air duct and en-
6
sure that the fan cable is pulled out