the display switches between them. Select your user by pres-
sing the
/
button.
Deleting scale data
If you would like to completely delete all measurements and old
user data on the scale, switch on the scale and press the UNIT
button on the rear of the scale for approx. 6 seconds.
"CLr" will appear on the display for several seconds.
This is necessary if you would like to delete scale users who
have been set up incorrectly or are no longer required, for ex-
ample.
Replacing the batteries
Your scale is equipped with a low battery indicator. If you ope-
rate the scale with flat batteries, "Lo" will appear on the display
and the scale will automatically switch o . In this case, the bat-
teries must be replaced (3 x 1.5 V AAA).
NOTE:
• When replacing the batteries, use batteries of the same
type, make and capacity.
• Do not use rechargeable batteries.
• Use batteries free from heavy metals.
9. CLEANING AND MAINTENANCE
The device should be cleaned from time to time.
This should be done using a damp cloth and, if necessary, a
small amount of detergent.
IMPORTANT
• Never use abrasive solvents or cleaning products!
• Never submerge the device in water!
• Do not clean the device in a dishwasher!
10. WHAT IF THERE ARE PROBLEMS?
If the scale encounters an error during measurement, the fol-
lowing is displayed:
Display
Cause
U -
Unknown
measurement as
it is outside the
user assignment
limit or a unique
assignment is not
possible.
BF Err
The proportion of
fat is outside the
measurable range
(less than 3% or
greater than 65%).
oLd
Maximum weight
capacity of 200 kg
exceeded.
Incorrect
Surface scale is
weight is
placed on is not
displayed.
even and hard e.g.
carpet.
Incorrect
Not standing still.
weight is
displayed.
Solution
Select your user by
pressing the
/
buttons.
Please repeat the
measurement
barefoot, or with
the soles of the feet
lightly dampened if
necessary.
Loads must not
exceed 200 kg.
Place the scale on an
even, hard surface.
Stand as still as
possible.
14
Display
Cause
Incorrect
Incorrect zero point
weight is
of scale.
displayed.
Lo
The batteries in the
scale are flat.
BF - - -
BIA measurement
not possible.
11. DISPOSAL
Empty, completely flat batteries must be disposed of through
specially designated collection boxes, recycling points or elec-
tronics retailers. You are legally required to dispose of the bat-
teries.
The codes below are printed on batteries
containing harmful substances:
Pb = Battery contains lead
Cd = Battery contains cadmium
Hg = Battery contains mercury
For environmental reasons, do not dispose of the device in the
household waste at the end of its service life. Dispose of the
device at a suitable local collection or recycling point in your
country.
Dispose of the device in accordance with EC Directive
– WEEE (Waste Electrical and Electronic Equipment). If
you have any questions, please contact the local autho-
rities responsible for waste disposal.
12. TECHNICAL SPECIFICATIONS
Model:
BF 400
Dimensions:
31 x 31 x 2.8 cm
Weight:
2170 g
Measurement
5-200 kg
range:
Subject to technical changes.
13. WARRANTY
Further information on the warranty and warranty conditions
can be found in the warranty leaflet supplied.
Solution
Wait until the scale
switches itself o .
Activate the scale,
wait for "0.0 kg" to
appear and take the
measurement again.
Replace the batteries
in the scale.
Please repeat the
measurement
barefoot, or with
the soles of the feet
lightly dampened if
necessary. Remain
on the stainless steel
electrodes after weight
measurement, until the
body analysis values
are displayed.
BF 410
35 x 30 x 2.8 cm
2660 g

Werbung