(decimal)
70
OUT2
71
Q2Type
72
QALow
73
QAHigh
94
8014485/YE12/2014-08-20 © SICK AG • Level sensors • Germany • Subject to change without notice
8 IO-Link
Format
Access
8-bit
R/W
unsigned
8-bit
R/W
unsigned
16-bit
R/W
unsigned
16-bit
R/W
unsigned
Value
0 Normally
Switchover,
open - free
normally closed/normally open
hysteresis
1 Normally
closed - free
hysteresis
2 Normally
open - window
function
3 Normally
closed - win-
dow function
4 Error sig-
nal, normally
open
5 Error sig-
nal, normally
closed
0 PNP
Determination of the type Q2
1 NPN
2 Drive
Lower signal point of the analog
output at the probe end in mil-
limeters.
For this level, the analog output
displays 4 mA or 0 V when
QAPOL=0. When QAPOL=1, the
analog output displays 20 mA
or 10 V.
Upper signal point of the analog
output at the process connec-
tion in millimeters.
For this level, the analog output
displays 20 mA or 10 V when
QAPOL=0. When QAPOL=1, the
analog output displays 4 mA
or 0 V.
LFP Inox
Description