Herunterladen Inhalt Inhalt Diese Seite drucken

SICK LFP inox Betriebsanleitung Seite 93

Tdr-füllstandsensor
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

LFP Inox
Index
Name
(decimal)
16
Vendor name
17
Vendor text
18
Product name
19
Product ID
21
Serial number
22
Hardware
version
23
Firmware
version
24
Application
Specific
Name
SICK-specific
Index
Name
(decimal)
64
SP1
65
RP1
66
OUT1
68
SP2_FH2
69
RP2_FL2
8014485/YE12/2014-08-20 © SICK AG • Level sensors • Germany • Subject to change without notice
8 IO-Link
Format
Access
8 x 8 bit
R
8 x 8 bit
R
8 x 8 bit
R
8 x 8 bit
R
8 x 8 bit
R
8 x 8 bit
R
8 x 8 bit
R
16 x 8 bit
R/W
Format
Access
16-bit
R/W
unsigned
16-bit
R/W
unsigned
8-bit
R/W
unsigned
16-bit
R/W
unsigned
16-bit
R/W
unsigned
Value
SICK AG
Name of the manufacturer
http://www.
URL of the manufacturer's
sick.com
homepage
LFP
Name of the device
String
IO-Link identification
number for the IODD
String
Device serial number
String
Version of the LFP hardware,
e.g., v 1.0
String
Version of the LFP firmware
e.g., v 1.0
String
Measuring point designation
(16 characters)
can be freely defined by
the customer
Value
Switching point Q1
Reset switching point Q1
0 Normally
Switchover,
open - free
normally closed/normally open
hysteresis
1 Normally
closed - free
hysteresis
Switching point Q2 in switching
operation. Middle of the upper
edge of the window in window
operation
Reset switching point Q2 in
switching operation. Middle of
the lower edge of the window in
window operation
EN
Operating instructions
Description
Description
93

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis