Herunterladen Inhalt Inhalt Diese Seite drucken

Factory Settings - Sick Lfp Inox Betriebsanleitung

Tdr-füllstandsensor
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

LFP Inox

9.9 Factory settings

Parameter
Factory setting
SP1
80% of the probe length measured from the end of the probe
RP1
5 mm below SP1
OU1
Q1_Hno
For 5-pin versions: 20% of the probe length measured from the end of the probe
SP2
For 8-pin versions: 60% of the probe length measured from the end of the probe
RP2
5 mm below SP2
OU2
Q2_Hno
TYP2
Q2_PNP
QAHigh
50 mm below start of probe
QALOW
10 mm above end of probe
QAPOL
QA_Nrm
QATYP
Auto
QAFAIL
3.5 mA
SimCur
SimOff
SimVol
SimOff
DspVal
Distan
Filter
Off
SimLev
SimOff
TrsHld
100
MaxCol
Depending on measuring mode : HiSped = AnySped, HiAcc = 10 cm/s
MeasMd
Depending on probe length: < 2005 mm = HiSped, > 2005 mm = HiAcc
CalRng
6005mm
FomSta
inactive
Limit
90
Offset
0 mm
Unit
mm
Lock
inactive
8014485/YE12/2014-08-20 © SICK AG • Level sensors • Germany • Subject to change without notice