5. Commissioning and operation
Tuning fork body, 42 mm [1.65 in]
Mounting situation
Tuning fork mounted vertically downwards
EN
Tuning fork mounted vertically upwards
Tuning fork mounted horizontally
Tuning fork length, 42 mm [1.65 in]
Switch point
Switch point accuracy:
Switch hysteresis:
Repeat accuracy:
Response time:
5.3 Mounting
Observe the torque values of the screw specified in pipefitting work.
In the selection of the mounting material (seals, screws, washers and nuts), take
the process conditions into account. The suitability of the seal must be specified
with regard to the medium and its damping. In addition, ensure it has corresponding
corrosion resistance.
16
Switch point
13 mm [0.51 in], measured from the lower
edge of the vibrating body tip
32 mm [1.3 in], measured from the upper edge
of the fork extension
4 mm [0.16 in] above the centre of the tuning
fork
±2 mm [±0.08 in]
≤ 3 mm [≤ 0.12 in]
0.1 mm [0.004 in]
Immersing into the medium 0.5 seconds
Emerging from the medium 1.0 seconds