Herunterladen Inhalt Inhalt Diese Seite drucken

Direct Current (Dc); Ac Voltage; Dc Voltage - Voltcraft Vc331 Bedienungsanleitung

200a ac/dc mini-zangenmessgerät
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Range
Crest factor (CF):
Crest factor 1.0 – 2.0 : +3 % deviation
Crest factor 2.0 – 2.5 : +5 % deviation
Crest factor 2.5 – 3.0 : +7 % deviation

12.4.4 Direct current (DC)

Range
20.00 A
200.0 A
Overload protection: 200.0 A
Accuracy: After successful zero adjustment

12.4.5 AC voltage

Range
2.000 V
20.00 V
200.0 V
600 V
Overload protection: 600 V ; Frequency range: 45 - 400 Hz ; Impedance: 10 MΩ
Crest factor (CF):
Crest factor 1.0 – 2.0 : +3 % deviation
Crest factor 2.0 – 2.5 : +5 % deviation
Crest factor 2.5 – 3.0 : +7 % deviation

12.4.6 DC voltage

Range
200.0 mV
58
Resolution
Resolution
0.01 A
0.1 A
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 mV
Accuracy
Accuracy
±(2 % +3)
±(2 % +3)
Accuracy
±(1.0 % +3)
±(1.0 % +3)
±(1.0 % +3)
±(1.2 % +3)
Accuracy
±(1.0 % +8)