10 Cleaning

Risk of electric shock! Disconnect the product from any input signals
and switch the power OFF before cleaning.
Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical
solutions. They damage the housing and can cause the product to malfunc-
tion.
– Do not immerse the product in water.
Clean the product with a clean, lint-free, antistatic cloth. Lightly moisten if
needed.
Check to make sure the clamp mating surface is clean. Trapped dirt or debris
can result in measurement errors.
54
1. Set the rotary switch to: NCV.
à
"NCV" and "EF" will appear on the dis-
play.
2. Place the sensor tip near the conductor.
à
If AC voltage is present, the tri-colour
LED will light and a beep will sound.
3. If the detected voltage increases:
à
the beeping will get faster.
à
the tri-colour LED changes from
green → yellow → red.
4. Switch the power OFF after use.