Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; General - Voltcraft Vc331 Bedienungsanleitung

200a ac/dc mini-zangenmessgerät
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Batteries/rechargeable batteries containing hazardous substances are
labelled with this symbol to indicate that disposal in household waste is
forbidden. The abbreviations for heavy metals in batteries are:
Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) bat-
teries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municip-
ality, our stores or wherever (rechargeable) batteries are sold. You thus fulfil your
statutory obligations and contribute to environmental protection.
Batteries/rechargeable batteries that are disposed of should be protected against
short circuit and their exposed terminals should be covered completely with insu-
lating tape before disposal. Even empty batteries/rechargeable batteries can con-
tain residual energy that may cause them to swell, burst, catch fire or explode in
the event of a short circuit.

12 Technical data

12.1 General

Power supply............................ 2x AAA 1.5 V batteries
Measuring categories ............... CAT II 600 V
Current measurement (AC) ...... max. 200 A
Display...................................... 2000 counts
Clamp opening range ............... 16.5 mm
Automatic shut-off..................... approx. 15 mins
Display type.............................. EBTN
Pollution degree........................ 2
Operating altitude ..................... max. 2000 m (above sea level)
Operating temperature ............. 0 to +40 °C
Operating humidity ................... <75 % RH (0 to +30 °C)
56
CAT III 300 V
(2 – 3 renewals/sec.)
<50 % RH (+30 to +40 °C)