NOTE
Do not plug the charger connecting cable into the mobile workstation socket strip because this
will not charge the batteries.
WARNING
The following regulations apply to charging:We recommend fusing the socket with a 16A
automatic circuit breaker with a C characteristic.
Check the charging cable for visible damage before charging.
Ensure the room in which the mobile workstation is charged is adequately ventilated.
Do not smoke or use naked flames when handling batteries.
Ensure no inflammable materials or spark-generating equipment is within a radius of at
least two metres of the mobile workstation during charging.
Keep fire extinguishing equipment ready.
Do not place metal objects on top of the batteries. Do not place objects directly on top of
the batteries.
Mode 3: charging and operation
You can continue working with the mobile workstation while it is in charging and operation mode.
Do not switch off the MAX BE Li-Ion mobile workstation for charging and plug the charger connection cable
into a stationary 230 V AC shockproof socket. You will see that the charging process has begun by looking
at the front of the battery controller; the display in percent will rise slowly after plugging in..
CAUTION
The charging cycle in Mode 3, charging and operation, depends on the connected consumers. The
battery charging time increases with the number of consumers.
CAUTION
Please note that the ambient temperature during charging must be at least 15°C in order to
achieve a sufficient charge state within the specified charging time.
WARNING
After switching off due to overloading or overheating, the converter attempts to switch on again
automatically. The time up to automatic switching on again can range from a few seconds to a
number of hours.
This is why it is important during work on the electrical system or the consumers to disconnect
the converter from the battery using the On/Off switch, unplug the low-power cable of the charger
and unplug the battery tray connection cable.