CAUTION
The charging cycle in Mode 3, charging and operation, depends on the connected consumers. The
battery charging time increases with the number of consumers. In the case of larger loads, full
charging of the batteries cannot be guaranteed, which can shorten the service life of the batteries.
After operation in Mode 3, the batteries should be fully charged. Adjust the function to the
connected consumers.
CAUTION
Please note that the ambient temperature during charging must be at least 15°C in order to
achieve a sufficient charge state within the specified charging time.
NOTE
The power-on status and the active charge mode can be determined on the internal charger by
watching the LEDs 'power' and 'status'. The battery cover must be removed for this purpose.
Green LED on
Green LED off
Yellow LED flashes quickly
Yellow LED flashes slowly
Yellow LED on
Yellow LED off
Figure 6: Charging Status LED
After successful charging
the charger switches automatically to charge holding
Disconnect the plug and close the rear panel of the mobile workstation. Now the mobile workstation is ready
for operation again.
MAX BE_Kurzanleitung_Brief_Overview_V1.00_de_en
- Charger on
- Charger off
- Bulk
- Constant voltage/Reconditioning/Updating
- Float/Power supply mode
- Storage
(depending on the charge state, the charging time can be between 5 and 10 hours)
61 / 100