MAINTENANCE PLAN
Always perform in the
here specified operating hour intervals
Maintenance task
Check condition
Motor oil
Check condition
Air filter
Spark plug
Valve movement
Visual inspection
Fuel line
and replacement
Fuel tank strainer
Fuel tank
Carburettor - 
setting tank
setting tank screw
Carburettor
Combustion chamber
Fuel valve
Electrical part/
gas part
ATTENTION
y Tasks marked with the X
formed only by an authorised service centre for
the HERON® brand and tasks marked with X
by a qualified inspection technician, see below.
Other tasks may be performed by the user
themselves.
NOTE
X
Perform the first oil change after the first 5 hours of
(1)
operation because there may be fine metal dust from
the engine's bores present in the oil, which may cause
the oil sensor to short-circuit.
X
An inspection of the clogging condition of the
(2)
air filter must be performed each time before the
generator is put into operation, since a clogged air
filter prevents the supply of combustion air into
the engine, which leads to its clogging, etc. Clean
the filter every 50 hours of operation according
to the described procedure, when used in a dusty
105
Before
every use
X
Replacement
X
(2)
Cleaning
Inspection,
adjustment
Replacement
 
Inspection - 
adjustment
X
(5)
of tightness
Inspection
if necessary
Cleaning
Cleaning
Draining via
Cleaning
Cleaning
Cleaning
Inspection/
maintenance
symbol must be per-
(3)
(4)
ATTENTION
y Not adhering to the servicing tasks in the maintenance
intervals provided in table 2 may lead to a malfunction
or damage of the generator, which is not covered by the
free warranty repair.
Every 50
After first
oper. hours
5 hours of
or more
operation
frequently
X
(1)
X
(2)
 
 
Every 2 calendar years (replacement as necessary) / X
After every 500 operating hours / X
After every 500 operating hours / X
After every 500 operating hours / X
Every 12 months from purchase / X
environment clean the filter every 10 hours or more
frequently depending on the dustiness of the envi-
ronment. In the event of heavy soiling or wear and
tear/damage, replace it with a new original part
from the manufacturer (the air filter for the given
generator model can be ordered under the number
listed in table 1). The generator must not be ope-
rated without an air filter or without an original air
filter from the manufacturer, which has the neces-
sary porosity and filtration effectiveness that is
necessary for the proper operation of the engine.
X
These maintenance points may only be performed by
(3)
a service centre authorized for the Heron® brand. The
performance of the tasks by a different service centre
or by the user themselves will be assessed as unautho-
rised tampering with the product, the result of which is
the voiding of the warranty (see Warranty conditions).
X
ATTENTION
(4)
According to current regulations in force for the
inspection of electrical and gas equipment, the inspe-
ction and checks of power generators may only be
Every 100
Every 300
oper. hours
oper. hours
X
X
 
X
 
X
(3)
 
(3)
(3)
X
X
(3)
(3)
X
(3)
(4)
Table 2