There is a danger of choking or suffocating!
Before connecting the machine, make certain that the data on the type
plate matches with the mains power data.
• Check the device for transport damage. Immediately report any dama-
ge to the transport company that delivered the electrical tool.
• Long supply cables (extension cable) should be avoided.
• Do not operate the electrical tool in damp or wet areas.
• Operate the electrical tool only in suitable areas (well ventilated).
9. Assembly
m Attention!
Always make sure the device is fully assembled before commissioning!
m Before connecting the machine to the mains power, make certain
that the data on the type plate matches with the mains power data.
m Attention! Always pull out the mains plug before carrying out ad-
justments on the device.
9.1 Assembling the base plate and column (fig. 2)
1. Slide the quick clamp (2) over the column (3).
2. Set the column (3) into the base plate (1) such that the guide pins on
the bottom end of the column (3) engage with the groove in the mount
on the base plate (1).
3. Tighten the pre-assembled fastening screws (A) on the rear of the
base plate (1) with the Allen key (L).
9.2 Fitting the parallel stop (fig. 3
1. Slide the parallel stop (16) into the grooves in the base plate (1).
2. Ensure that the sliding blocks underneath the wing screws of the par-
allel stop (15) are properly engaged in the grooves of the base plate.
3. Move the parallel stop (16) to the desired position and tighten the
wing screws of the parallel stop (15) firmly.
50 | GB
www.scheppach.com