To reduce the risks associated with chemical exposure, impact, crush, tipping
hazards, property damage from product loss, bypass or cross contamination due to
pressure barrier failure, connector failure, purifi cation media or capsule failure:
• Do not expose the purifi cation capsule to base sanitization chemicals for more than
60 minutes.
• Do not pressurize the capsule more than 5 psi during introduction of NaOH solution
and static soak during sanitization.
• Use only 70% ethyl and/or isopropyl alcohol to wipe the exterior of the capsules.
• Do not use with or expose this product to pressurized steam or sanitizing chemicals
other than NaOH.
To reduce the risks associated with chemical exposure due to pressure barrier
failure, connector failure, purifi cation media or capsule failure from use of
disinfectants within the product:
• Use up to 1 M Sodium Hydroxide (NaOH) for pre-use and post-use sanitization and up
to 5% Bleach (NaClO) for post-use sanitization
• Do not expose the purifi cation capsule to base sanitization chemicals more than
60 minutes.
• Do not pressurize the capsule more than 5 psi during introduction of NaOH solution
and static soak during sanitization.
• Wear personal protective equipment (PPE) to prevent chemical splash.
To reduce the risk of burn or exposure injuries associated with autoclave sterilization.
• Wear personal protective equipment (PPE) to handle hot capsules.
To reduce the risk of fl uid exposure:
• Evaluate the risk of your process liquids and determine an appropriate protocol to
dispose of spent capsules and all other waste.
• Dispose of capsules and all other waste in accordance with federal, state, and local
regulations or your local country's laws and regulations.
• The protective caps on the capsule connections are designed for the protection of
capsule parts. The protective caps are not intended to contain process liquids during the
disposal of spent capsules.
Table of Contents
1. Operating Parameters and Product Specifi cations . . . . . . . . . . . . . . . . page 5
2. Single Stage Use Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
3. Capsule Use with Pre-use Autoclave Sterilization . . . . . . . . . . . . . . . . .page 8
4. Capsule Use with Pre-use NaOH Sanitization . . . . . . . . . . . . . . . . . . . . .page 9
5. Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
WARNING
WARNING
CAUTION
CAUTION
-4-

Werbung

loading