If the new code as per 13) was incorrectly confi rmed, the signal 3 x
Repeat the sequence from 6).
By pressing the key combination P and 0 all the functions programmed (secondary code,
dual code, time delay, opening window) are deleted.

4.7.2 Locking

1) Turn key counter clockwise until stop position reached
2) Remove key and keep in a safe place
Turn the shaft mounting back to the original position with the aid of the drive shaft
3)
(square end). The position of the screw in the shaft mounting must be turned towards
the drilled hole in the control unit provided for the Allen key (see fi gure 3)
Replace the bar handle in the original position. The screw in the bar handle must be
4)
turned towards drilled hole in the control unit provided for the Allen key
Screw tight into the shaft fi tting using the Allen key (secure shaft and button against
5)
being pulled off)
6) Remove Allen key

4.7.3 Cancellation of signals

If the aluminium control unit has been completely unscrewed the lock's electronic systems
recognise and record this. An appropriate alarm signal then appears every time the lock is
opened. The cancellation of this signal can only be done by the primary code holder (in paral-
lel mode) or by the dual code holder (in ordinary dual code mode) (see 4.5.2).
Page 42
82132 Code-Combi B
appears.