GB
If the new code as per 15) was incorrectly confi rmed, the signal 3 x
Repeat the sequence from 8).
By pressing the key combination P and 0 all the functions programmed (secondary code,
dual code, time delay, opening window) are deleted.
4.6.2 Locking
1) Turn key counter clockwise until stop position reached
2) Remove key and keep in a safe place
3) Dismantle cover plate with tool (see 4.6.1 1) - 4))
4) Insert drive shaft with the drilled hole fi rst
Put on bar handle (taking into consideration the original position
5)
of the handle)
6) Replace cover plate and click on all four catches
Cancel alarm (can only be done by primary code holder (in parallel
7)
mode) or by the dual code holder (in ordinary dual code mode)):
7a) Press ON
7b) Press P
7c) Enter valid 6-digit primary code
7d) Press P
7e) Press 9
Page 40
82132 Code-Combi B
appears.
/
/
/
/
/
/
1 x
Kaba Mauer GmbH