Installation instructions, only for experts
Setting the operating mode for the additional output
The additional output can either be regulated or switched on and off. The dimmer
switch function is activated or deactivated using the function selection switch 8.
● The function selection switch 8 is set to the ON position as standard. The dim-
mer switch function is therefore activated.
● If you wish to deactivate the dimmer switch for the additional output, place
the function selection switch 8 in the OFF position.

8.2. Settings in the technician menu

Opening the technician menu
Additional settings can be made in the technician menu. To access the technician
menu, perform the following steps:
1. Switch off the sauna control unit.
2. Press the bottom knob and the ON/OFF switch at the same time.
► In the top display, "SEtt" appears briefly.
► The two knobs flash.
The settings are saved as soon as you close the technician menu
(see page 29).
Activating single-sensor mode
In single-sensor mode, the sauna control unit is operated with the heater sensor
with an excess temperature fuse (F1) only. The two-sensor mode is activated as
standard. If you wish to activate the single-sensor mode, perform the following
steps:
1. Open the technician menu (see 26).
2. Turn the top knob to the temperature symbol (position A – see point 9.2 on
page 30).
► The temperature symbol flashes.
► In the top display, "SEnB" appears.
► In the bottom display, "On" appears.
("On" means that the two-sensor mode is activated.)
3. Turn the bottom knob to the left.
► In the bottom display, "OFF" appears.
► The single-sensor mode is activated.