PLEASE NOTE! Improper care can lead to impairment of the device or even its
destruction.
1. Housing surfaces must be cleaned with a clean, damp cloth. Make sure that no moisture can
penetrate the device.
2. Air inlets and outlets must be regularly cleaned of dust and dirt. If compressed air is used, make
sure that damage to the device is prevented (e.g. fans must be blocked in this case, as they
could otherwise over-rev.).
3. Lines and plug contacts must be cleaned regularly and dust and dirt must be removed.
4. In general, no cleaning agents or abrasive agents may be used, otherwise the surface finish
may be damaged.
5. Devices must generally be stored dry and protected from dust and dirt.
6. To ensure correct and safe operation, all accessible or removable lenses and light-emitting
apertures must be cleaned regularly.
MAINTENANCE AND REPAIR (by qualified personnel only)
HAZARD! There are live components in the device. Even after disconnecting the
mains connection, there may still be residual voltage in the device, for example, due
to charged capacitors.
PLEASE NOTE! Maintenance and repair work may only be carried out by sufficiently
qualified specialist personnel. If in doubt, consult a specialist workshop.
PLEASE NOTE! Improperly performed maintenance work may affect the warranty
claim.
PLEASE NOTE! For conversion or retrofit sets provided by the manufacturer, it is
essential to observe the enclosed installation instructions.

REPLACING GOBOS

CAUTION: Gobo replacement must only be carried out by qualified personnel. If you
are not qualified to do this, do not try to replace gobos yourself. Refer instead to
professional companies.
CAUTION: When carrying out any work, make sure that no foreign bodies enter the
housing! When replacing the gobos, make sure that the gobos are inserted correctly
into the corresponding gobo bracket, otherwise heat damage to the gobos and gobo
brackets may occur!
ATTENTION: In order to maintain the IP65 tightness of the OTOS SP6 moving head,
a new gasket must be inserted at the appropriate location after replacing a gobo.
Carefully follow each step in the instructions below.
After mounting the cover, perform a leak test.