            Screw out the spark plugs and allow approx. 1 teaspo-
on of motor oil to flow into the cylinder, and then pull
the handle of the manual starter 2-3×. This will create
an even protective oil film in the area of the cylinder.
Then screw the spark plug back in.
            Pull on the handle of the manual starter and stop the
piston in the top end position. In this way, the exhaust
and suction valve will remain closed.
            Place the generator into a safe dry room.
XI. Diagnostics and
troubleshooting
potential faults

ENGINE WILL NOT START

y Is the power switch in the "ON" position?
y Is the fuel valve for the supply of petrol open?
y Is there sufficient fuel in the tank?
y Is there a sufficient amount of oil in the engine?
y Is the ignition cable connector connected to the spark
plug (the generator has 2 spark plugs)?
y Is a spark being generated on the spark plug (the gene-
rator has 2 spark plugs)?
y Do you have old stale petrol in the fuel tank? (Add a pet-
rol conditioner to the petrol and stir it in by moving the
generation or by pouring another portion of the fuel
over it and allow it to act, see fig. 5. chapter IV.)
If you are unable to remedy the fault, have the repairs perfor-
med at an authorised service centre for the HERON® brand.
XII. Meaning of markings
and pictograms
y All technical parameters specified on the rating label
are provided in chapter II. Technical specifications.
AC 230 V ~50 Hz
GENERATOR
Max. P
12 kW
el.
P
11 kW
el.(COP)
47.8 A | cos ϕ   1
I
(COP)
17.5 kW / 3 600 min
ENGINE
IP23M | 190 kg | OHV | 12 V 8.3 A DC | class G2 (ISO 8528-1)
Quality class A (ISO 8528-8) | Max. 1000 m | T: -15° to +40°C
p r 100 kPa ( ~1 atm. ) | Serial number (see engine)
Generator • Zdrojové soustrojí • Zdrojový agregát • Áramfejlesztö • 
Stromaggregat • Генератор електричної енергії
Produced by Madal Bal a.s. • Prům. zóna Příluky 244 • CZ 76001 Zlín • Czech Republic
EN
8896431
AC 400 V ~50 Hz
Max. P
12 kW (15 kVA)
el.
P
11 kW (13.75 kVA)
el.(COP)
19.9 A | cos ϕ  0.8
I
F(COP)
-1
| 750 cm3
Pictogram
Meaning
Attention/warning
Read the user's manual before opera-
ting the pressure cleaner.
When present in the vicinity of the
generator, use certified hearing prote-
ction with a sufficient protection level
rating. The effect of the noise may
induce irreversible hearing damage.
The generator must not be operated
in indoor areas and in insufficiently
ventilated environments, e.g. in out-
door holes or trenches, etc., where the
exhaust gases are not sufficiently ven-
tilated. The exhaust gas is toxic. Risk of
poisoning by carbon monoxide.
Danger of burns.
Do not touch the hot surface.
Electrical equipment. Risk of injury by
el. shock when used incorrectly with
respect to this fact.
Fire hazard.
Never cover the generator.
Do not expose the generator to rain
and high humidity.
Prevent the access of any flame or spark
sources. Risk of ignition of flammable
fumes - particularly when refilling fuel.
Do not extinguish using water.
Grounding terminal.
It meets the respective EU harmoni-
sation legal directives.
Electrical equipment at the end of its
lifetime must not be thrown out into
communal waste, see below.
Serial number. Represents the year
Serial
and month of manufacture and pro-
number (SN)
duction batch designation