Herunterladen Inhalt Inhalt Diese Seite drucken

Operator Positions; Safety Measures During Operation; Safety Devices; Safety Check - Optimum OPTIgrind GH 10T Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Check if the machine is zero potential.
1.6

Operator positions

The operator's position is in front of the drill bit grinder.
INFORMATION
The mains plug of the drill bit grinder must be freely accessible.
1.7

Safety measures during operation

CAUTION!
Risk by inhaling health hazardous dusts and fogs.
Depending on the materials which need to be treated and the agents which are used,
dusts and fogs may be generated which endanger your health.
Make sure that the generated health hazardous dusts and fogs are safely sucked-off at
the place of origin and that they are dissipated or filtered. To do so, use a suitable
extraction unit.
1.8

Safety devices

Use the drill bit grinder only with properly functioning safety devices.
Stop the drill bit grinder immediately if there is a failure on the safety device or if it is not
functioning for any reason. It is your responsibility!
If a safety device has been activated the drill bit grinder must only be used if you
have removed the cause of the failure,
have verified that there is no danger resulting for the staff or objects.
WARNING!
If you bypass, remove or deactivate a safety device in any other way, you are
endangering yourself and other staff working with the drill bit grinder.
The possible consequences are:
extremely serious injuries by bursting of the abrasive wheel,
injury of eyes due to flying sparks,
injury of hands,
a fatal electrocution.
WARNING!
The separating protective covers which are made available and delivered together with
the machine are designed to reduce the risk of workpieces or fragments of tools or
workpieces flying off at high speed - however, this cannot be completely avoided.
Always work carefully and observe the limit values of your grinding process.
1.9

Safety check

Check the drill bit grinder before each start-up or at least once per shift. Inform the person
responsible immediately of any damage, defect or change in operating function.
Check all safety devices
at the beginning of each shift (at continuous operation),
once a week (with the machine in operation),
after every maintenance and repair work.
Check that prohibition, warning and information signs and the labels on the drill bit grinder,
are legible (clean them, if necessary),
are complete (replace if necessary).
EN
GH 10T | GH 15T
40
Originalbetriebsanleitung
Safety
Version 1.1.4 - 2022-09-23

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Optigrind gh 15t310 0110310 0115

Inhaltsverzeichnis