520 Reactive power control
C Cos Phi:
ind 1,00
D Cos Phi:
ind 1,00
520 Reactive power control
Mode:
Q (U)
Lower Q/Sn: cap ---%
Lower Q/Sn: cap ---%
Low Vlim:
---V
High Vlim:
---V
Hysteresis:
---V
Delay Time:
-.--s
520 Reactive power control
Mode:
Fixed Q
Q/Sn:
cap ---%
16.3.11 Diagnostic and Alarm (600)
The reports that are displayed depend on the grid that has
been set:
●
Internal log (is always displayed)
●
LVD report (only shown for LVD grids)
●
Italian Autotest (only shown for Italian grids)
600 Diagnostic&Alarm
610 IT Autotest
620 Internal log
640 LVD Reports
16.3.12 Software version/inverter data (700)
700 Inverter info
710 Software vers.
720 Inverter data
16.3.13 Standard menu (800)
800 Standard menu
Menu number:
Operation and installation manual for SOLIVIA 11 EU G4 TR
Explanation
inductive / capacitive ||
1.00 ... 0.8
inductive / capacitive ||
1.00 ... 0.8
Explanation
inductive / capacitive ||
0 ... 60 %
inductive / capacitive ||
0 ... 60 %
184 ... 230 V
230 ... 266 V
0 ... 50 V/Hz
0 ... 655 s
Explanation
inductive / capacitive ||
0 ... 60 %
Explanation
Autotest for Italian grids. Con-
tains the last five reports.
Firmware update
Report as per VDE AR N 4105.
Contains the last five failure
messages.
Explanation
Version of the installed soft-
ware
Production date and serial
number
Explanation
Number of the menu that is to
be displayed as the standard
menu.