Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7. Installation
7.3.4

I/O interface

Plug assembly
The I/O interface connection kit is supplied in the scope of
delivery.
Fig. 7.8.:
Assembly of the I/O connection
No.
Designation
Cover
Plug housing
Seal for unused openings
Clamping cage
Cable collar
Cable
Sealing ring
I/O interface
The two openings for the cable feed-through are designed
for cable diameters of 3.6 to 5.2 mm. Unused openings
must be closed using the seal
Fig. 7.9.:
Wiring of the I/O connection
24
.
1
10
Pin assignments
Pin
Designation
1
2_COM
2
2_NOC
3
1_COM
4
1_NCC
5
1_NOC
6
A
7
B
8
IN
9
5 V
10
GND
Fig. 7.10.:
Relay 1 pin assignment
Fig. 7.11.:
Relay 2 pin assignment
Use
Relay 2 – common
Relay 2 – contact open when not
energized
Relay 1 – common
Relay 1 – contact closed when not
energized
Relay 1 – contact open when not
energized
Feeding off – wire A
Feeding off – wire B
Reserved
Reserved
Reserved
1_NOC
1_NCC
1_COM
2_NOC
2_COM
Operation and installation manual for SOLIVIA 11 EU G4 TR