PROFINET, Dokumentation
Parameter
Block Type
Block Length
Block Header
Block Version High
Block Version Low
Manufacturer ID
Order ID
Serial Number
Hardware-Revision
Software-Revision Prefix
Sofware-Revision X
Software-Revision Y
Software-Revision Z
Revision Counter
I&M0
Profile ID
Profile specific type
IM Version
IM Supported
Abb. 33 Struktur I&M0-Record, Index: 0xAFF0, Zugriff: Read-Only
optoNCDT 1900 / Profinet
Datentyp
Info
UINT16
0x0020
UINT16
0x0038
UINT8
0x01
UINT8
0x00
UINT16
0x0426 (MICRO-EPSILON Messtechnik GmbH)
UINT8(20)
„4120xxx.001"
UINT8(16)
UINT16
z. B. 0x0003
Character describing the software of the (sub) module.
UINT8
Allowed values: 'V', 'R', 'P', 'U' and 'T'
UINT8
Function Enhancement (Major Version Number)
UINT8
Bug Fix (Minor Version Number)
UINT8
Internal Change (Build Version Number)
UINT16
Starting from 0, shall increment on each parameter change
UINT16
0
UINT16
5
UINT16
The I&M version. (Default value 0x0101)
Bit list describing the I&M variants supported by the (sub)
module:
0x02 -> I&M1 Supported
UINT16
0x04 -> I&M2 Supported
0x08 -> I&M3 Supported
0x10 -> I&M4 Supported
0x20 -> I&M5 Supported