Anhang | PROFINET Parameterliste
Name
Mittelung
Comp1 type
Average 1 number of va-
lues for moving average
Average 1 number of
values for median
Average 1 number of
values for recursive
Comp2 type
Average 2 number of va-
lues for moving average
Average 2 number of
values for median
Average 2 number of
values for recursive
Nullsetzen, Mastern
Master enable
Master set
optoNCDT 1900 / Profinet
Parameter-ID Datentyp
52000
UINT8
52001
UINT32
52002
UINT32
52003
UINT32
52010
UINT8
52011
UINT32
52012
UINT32
52013
UINT32
53001
BOOL
53003
BOOL
Wertebereich
0 - None
2 - Moving
1 - Median
3 - Recursive
2 - 2
...
4 - 4
2048 - 2048
8 - 8
4096 - 4096
3 - 3
7 - 7
5 - 5
9 - 9
2 - 2
5 - 5
3 - 3
...
4 - 4
32000 - 32000
0 - None
2 - Moving
1 - Median
3 - Recursive
2 - 2
...
4 - 4
2048 - 2048
8 - 8
4096 - 4096
3 - 3
7 - 7
5 - 5
9 - 9
2 - 2
5 - 5
3 - 3
...
4 - 4
32000 - 32000
0 - False
Signal DIST1 für Nullsetzen/Mastern bestim-
1 - True
men
0 - False
Nullsetzen bzw Mastern durchführen oder
1 - True
beenden
Beschreibung
Zugriff
Mittelungsart
rw
Anzahl Werte über die
gemittelt wird
rw
rw
rw
Mittelungsart
rw
Anzahl Werte über die
rw
gemittelt wird
rw
rw
rw
rw
Seite 114