Herunterladen Inhalt Inhalt Diese Seite drucken

Residual Risks; Assembly; Spark Protection Assemble/Set - Parkside PSBS 240 C2 Originalbetriebsanleitung

Stand-bandschleifer
Vorschau ausblenden Andere Handbücher für PSBS 240 C2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
GB
IE
workpiece on the workpiece
support. In this way, you reduce
the risk of injury from fl ying sparks
and maintain better control over the
workpiece to be machined.
e) Only use grinding discs where
the outside diameter, borehole,
thickness and maximum
rotational speed correspond
to the specifi cations of the
machine. In this way, you avoid
injuries.
f) Replace the worn grinding disc if
these distances can no longer be
maintained.
g) Replace any damaged or
heavily worn grinding discs.
h) Always use the power tool with
insert tools on both spindles to
limit the risk of contact with the rotating
spindle.
i) If replacement of the connecting cable
becomes necessary, this is to be carried
out by the manufacturer or its agent in
order to avoid safety risks.

Residual risks

Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Lung damage, if suitable respiratory
protection is not worn.
b) Hearing damage, if suitable ear pro-
tection is not worn.
c) Damages to health due to
- touching the area of the grinding tool
which was not covered;
- the ejection of pieces from workpiece
or damaged grinding discs.
d) Damage to your health caused by
swinging your hands and arms when
26
operating the appliance for longer pe-
riods of time or if the unit is not held or
maintained properly.
Warning! During operation, this
electric tool generates an electro-
magnetic fi eld which, under certain
circumstances, may impair the
functionality of active or passive
medical implants. To reduce the risk
of serious or lethal injuries, we rec-
ommend that persons with medical
implants consult their doctor and the
manufacturer of their medical im-
plant before operating the machine.

Assembly

Caution! Risk of injury!
- Ensure that you have suffi cient
space in which to work, and that
you do not endanger other people.
- Always fasten the device on to
the work surface with screws
featuring the suffi cient length and
thickness in order to maintain
control of the device.
- All covers and protective devices
must be assembled properly be-
fore commissioning.
- Disconnect the mains plug before
changing the setting on the device.
Spark protection
assemble/set
1. Screw the spark protection (1)
using the adjusting screw (2) and
the nut (2a) on to the protective
hood (3).
To do so, you will need a screw-
driver and a ring spanner
(AF 8 mm), used to hold it in
place.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis