Herunterladen Inhalt Inhalt Diese Seite drucken

Workpiece Supports Assemble/Set; Screw Device On To Workbench; Operation - Parkside PSBS 240 C2 Originalbetriebsanleitung

Stand-bandschleifer
Vorschau ausblenden Andere Handbücher für PSBS 240 C2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
2. Set the spark protection (1) with
the adjusting screw (2) so that the
distance between the grinding
disc (19) and the spark protection
is max. 2 mm (see small image).
Periodically readjust the spark pro-
tection in order to offset the wear
and tear of the grinding disc (dis-
tance max. 2 mm).
Workpiece supports
assemble/set
1. Screw the workpiece supports
(6/18) on to the device.
2 positions (see
possible for the tape loop.
2. To do so, use the screws (5a/17a),
washers (5b/17b), toothed lock
washer (5c/17c) and star grip
nuts (5/17) provided.
3. Set the workpiece support of the
grinding belt (19) with the star
grip nut (17) so that the distance
between the grinding disc (19)
and the workpiece support is
max. 2 mm (see small image).
Periodically readjust the workpiece
support in order to offset the wear
and tear of the grinding disc (dis-
tance max. 2 mm).
Screw device on to
workbench
Screw the device onto the work-
bench with 4 screws and nuts.
Insert the screws through the 4 bore
holes (13) on the base of the device.
The screws and nuts required for
assembly are not part of the scope
of delivery.

Operation

A + B) are
Caution! Risk of injury!
- Always disconnect the plug from
the mains socket before working.
- Use only grinding disks and acces-
sories recommended by the manu-
facturer. The use of other insertion
tools and other accessories may
cause risk of injury.
- Only use grinding tools which bear
information about the manufacturer,
type of binding, dimension and
permitted number of revolutions.
- Only use grinding discs where the
printed rotational speed is at least
as high as what has been specifi ed
on the name plate of the device.
- Do not use broken, cracked or other-
wise damaged grinding disks.
Change any damaged or heavily
worn grinding discs.
- Only use the device when both grin-
ding belt and the grinding disc are
assembled.
- Never operate the device without
the visual protection disk.
- Always use protective goggles even
if you are protected against sparks.
- Always inspect the grinding disc
before starting the device:
Check the distance between the
spark protection and grinding disc
as well as workpiece support and
grinding disc (distance maximum
2 mm).
- The grinding disc must be replaced
once the spark protection and
workpiece support on the grinding
disc do not have distance of max.
2 mm.
- Switch on the equipment only when
it is safely installed on the work sur-
face.
GB
IE
27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis